Produktbeschreibung
Produktbeschreibung
M/HBP R134A (110V-120V~60HZ/220V-240V~50HZ) Refrigeration Compressors Special for Home Dehumidifiers
Adopting high-quality components, SIXIHU (WEST LAKE) DIS. refrigeration compressors are always environmental friendly, high efficient, and widely praised by customers in the refrigeration industry due to its low noise, high performance, and long service life.
Merkmale:
1. Low Noise:
– There are 2 welding methods for the compressor casing: flange butt welding or insert welding. The thickness, shape, and internal cavity size of the shell have a significant impact on noise.
– There are 2 fixing methods for the movement: suspension spring type and seat spring type, with the seat spring compressor having less noise and vibration.
2. High Performance:
– Equipped with professional valve components. The valve group is the heart of the compressor and plays a significant role in the performance of the compressor.
3. Long Service Life:
– The crankshaft and connecting rod have good performance and are resistant to friction.
4. High Efficiency & Eco-friendly:
– As the power in a hermetic compressor, an electric motor converts electrical energy into mechanical energy, driving the piston to compress refrigerant vapor, enabling the refrigerant to circulate in the refrigeration system and achieve the purpose of refrigeration
Product Parameters
Compressor Technical Data: M/HBP R134A 110V-120V~60HZ/220V-240V~50HZ
| Serial | Modell | HP | V/Hz | Displacement (cm3) | Cooling Capacity ASHRAE | Motor type | Starting Device | Starting capacitor (uF) | Running capacitor (uF) | Cooling | Certificate | |||||||||||||||
| -15ºC(5F) | -10ºC(10F) | -5ºC(23F) | 0ºC(32F) | Test Conditions: 7.2ºC(45F) | 10ºC(50F) | |||||||||||||||||||||
| W | Btu/h | W | Btu/h | W | Btu/h | W | Btu/h | Capacity (W) | Capacity (Btu/h) | lnput Power(W) | Current (A) | COP (W/W) | EER (Btu/Wh) | W | Btu/h | |||||||||||
| L | GQR30TC | 1/10 | 220-240V/50-60Hz | 3.0 | 97 | 331 | 125 | 427 | 145 | 495 | 185 | 631 | 245 | 836 | 129 | 0.9 | 1.9 | 6.48 | 275 | 938 | RSIR | PTC/Heavy Hammer PTC/Current Starting Relay | / | / | F | CCC |
| GQR35TC | 1/9 | 3.5 | 135 | 461 | 175 | 597 | 195 | 665 | 265 | 904 | 385 | 1314 | 185 | 1.1 | 2.1 | 7.17 | 420 | 1433 | RSIR | / | / | F | CCC | |||
| GQR45TC | 1/6 | 4.5 | 176 | 601 | 230 | 785 | 280 | 955 | 350 | 1194 | 450 | 1535 | 204 | 1.2 | 2.2 | 7.51 | 485 | 1655 | RSIR | / | / | F | CCC | |||
| ML | GQR55TC | 1/6+ | 5.5 | 245 | 836 | 310 | 1058 | 390 | 1331 | 525 | 1791 | 575 | 1962 | 273 | 1.5 | 2.1 | 7.19 | 615 | 2098 | RSIR | / | / | F | CCC | ||
| GQR60TC | 1/4 | 6.5 | 335 | 1143 | 435 | 1484 | 545 | 1860 | 665 | 2269 | 705 | 2405 | 306 | 1.9 | 2.3 | 7.86 | 745 | 2542 | RSIR | / | / | F | CCC | |||
| GQR70TC | 1/4 | 7.0 | 370 | 1262 | 480 | 1638 | 595 | 2030 | 720 | 2457 | 765 | 2610 | 364 | 2.1 | 2.1 | 7.17 | 805 | 2747 | RSIR | / | / | F | CCC | |||
| MQ | GQR80TC | 1/4+ | 8.0 | 420 | 1433 | 550 | 1877 | 680 | 2320 | 810 | 2764 | 855 | 2917 | 388 | 2.2 | 2.2 | 7.52 | 895 | 3054 | CSIR | Heavy Hammer Current Starting Relay | 80 | / | F | CCC | |
| GQR90TC | 1/3- | 9.0 | 474 | 1617 | 621 | 2119 | 768 | 2620 | 910 | 3105 | 955 | 3258 | 434 | 2.3 | 2.2 | 7.51 | 995 | 3395 | CSIR | 80 | / | F | CCC | |||
| GQR11TC | 3/8 | 11.0 | 536 | 1829 | 702 | 2395 | 868 | 2962 | 1034 | 3528 | 1079 | 3682 | 469 | 2.9 | 2.3 | 7.85 | 1119 | 3818 | CSIR | 80 | / | F | CCC | |||
| MD | GQR12TC | 3/8+ | 12.0 | 606 | 2068 | 793 | 2706 | 981 | 3347 | 1168 | 3985 | 1208 | 4122 | 549 | 3.4 | 2.2 | 7.51 | 1248 | 4258 | CSIR | 80 | / | F | CCC | ||
| GQR14TC | 1/2 | 14.0 | 685 | 2337 | 896 | 3057 | 1108 | 3780 | 1320 | 4504 | 1365 | 4657 | 593 | 3.6 | 2.3 | 7.85 | 1305 | 4453 | CSIR | 80 | / | F | CCC | |||
| GQR16TC | 1/2+ | 16.0 | 754 | 2573 | 1012 | 3453 | 1252 | 4272 | 1492 | 5091 | 1535 | 5237 | 667 | 4.0 | 2.3 | 7.85 | 1575 | 5374 | CSIR | 80 | / | F | CCC | |||
| Serial | Modell | HP | V/Hz | Displacement (cm3) | Cooling Capacity ASHRAE | Motor type | Starting Device | Starting capacitor (uF) | Running capacitor (uF) | Cooling | Certificate | |||||||||||||||
| -15ºC(5F) | -10ºC(10F) | -5ºC(23F) | 0ºC(32F) | Test Conditions: 7.2ºC(45F) | 10ºC(50F) | |||||||||||||||||||||
| W | Btu/h | W | Btu/h | W | Btu/h | W | Btu/h | Capacity (W) | Capacity (Btu/h) | lnput Power(W) | Current (A) | COP (W/W) | EER (Btu/Wh) | W | Btu/h | |||||||||||
| L | GQR30TCD | 1/10 | 110-120V/60Hz | 3.0 | 118 | 403 | 150 | 512 | 174 | 594 | 225 | 768 | 295 | 1007 | 134 | 1.8 | 2.2 | 7.51 | 340 | 1160 | RSIR | PTC/Heavy Hammer PTC/Current Starting Relay | / | / | F | CCC |
| GQR35TCD | 1/9 | 3.5 | 162 | 553 | 210 | 717 | 234 | 798 | 320 | 1092 | 465 | 1587 | 211 | 2.0 | 2.2 | 7.52 | 504 | 1720 | RSIR | / | / | F | CCC | |||
| ML | GQR45TCD | 1/6 | 4.5 | 210 | 717 | 275 | 938 | 340 | 1160 | 420 | 1433 | 540 | 1842 | 245 | 2.1 | 2.2 | 7.52 | 580 | 1979 | RSIR | / | / | F | CCC | ||
| GQR55TCD | 1/6+ | 5.5 | 310 | 1058 | 390 | 1331 | 480 | 1638 | 610 | 2081 | 665 | 2269 | 316 | 2.9 | 2.1 | 7.18 | 720 | 2457 | RSIR | / | / | F | CCC | |||
| GQR60TCD | 1/4 | 6.5 | 378 | 1290 | 510 | 1740 | 650 | 2218 | 731 | 2494 | 786 | 2682 | 341 | 3.5 | 2.3 | 7.86 | 841 | 2869 | RSIR | / | / | F | CCC | |||
| GQR70TCD | 1/4 | 7.0 | 430 | 1467 | 545 | 1860 | 750 | 2559 | 806 | 2750 | 862 | 2941 | 410 | 3.8 | 2.1 | 7.17 | 917 | 3129 | RSIR | / | / | F | CCC | |||
| MQ | GQR80TCD | 1/4+ | 8.0 | 470 | 1604 | 625 | 2133 | 820 | 2798 | 907 | 3095 | 964 | 3289 | 438 | 4.2 | 2.2 | 7.51 | 1019 | 3477 | CSIR | Heavy Hammer Current Starting Relay | 93-169 | / | F | CCC | |
| GQR90TCD | 1/3- | 9.1 | 530 | 1808 | 695 | 2371 | 890 | 3037 | 1019 | 3477 | 1074 | 3664 | 488 | 3.8 | 2.2 | 7.51 | 1129 | 3852 | CSIR | 93-169 | / | F | CCC | |||
| GQR11TCD | 3/8 | 11.0 | 600 | 2047 | 772 | 2634 | 954 | 3255 | 1100 | 3753 | 1155 | 3941 | 502 | 5.2 | 2.3 | 7.85 | 1210 | 4129 | CSIR | 93-169 | / | F | CCC | |||
| MD | GQR12TCD | 3/8+ | 12.8 | 678 | 2313 | 872 | 2975 | 1034 | 3528 | 1270 | 4333 | 1325 | 4521 | 602 | 5.5 | 2.2 | 7.51 | 1380 | 4709 | CSIR | 93-169 | / | F | CCC | ||
| GQR14TCD | 1/2 | 14.2 | 758 | 2586 | 985 | 3361 | 1218 | 4156 | 1402 | 4784 | 1457 | 4971 | 633 | 5.8 | 2.3 | 7.85 | 1512 | 5159 | CSIR | 93-169 | / | F | CCC | |||
| GQR16TCD | 1/2+ | 15.3 | 829 | 2829 | 1113 | 3798 | 1375 | 4692 | 1641 | 5599 | 1696 | 5787 | 737 | 6.0 | 2.3 | 7.85 | 1751 | 5974 | CSIR | 93-169 | / | F | CCC | |||
→ More Compressor Please Click to Contact Us!
Company Profile
Zertifizierungen
With abundant technique force,we have our own researching, developing, manufacturing, inspecting and testingcenters, and imported the international advanced high-tech equipments. Our company has passed the ISO9001,ISO14001,OHS18001 international management system certificates. The products have got UL,ETL,CE,CB,and CCC certificates. Our products are not only selling strongly in more than 30 provincesand municipality,but also largely exporting to Europe,America,Australia,Middle East, Africa and South Asia. We have won an excellent reputation from the customers and friends by our product quality, price versus performance ratio and service.
Häufig gestellte Fragen
Q1: Are you a manufacturer or trader?
A1: ZHangZhoug Maidi Refrigeration Technology Co., Ltd. is a Hi-tech enterprise. We own the standard plant and office building which covering 21, 000 square meters. With abundant technique force, we have our own researching, developing, manufacturing, inspecting and testing centers, and imported the international advanced equipments.
Q2: How to match sikelan compressor to refrigeration?
A2: We have a professional team of engineers who provide technical support and online guidance on product installation and replacement.
Q3: How do you ensure quality?
A3: We have a dedicated product research and testing center with authoritative quality management system certification: ISO9001/ISO14001/OHS18001.
Q4:What’s CHINAMFG compressor usage scenario?
Q4:Our product could use in mobile applications e.g. cooling boxes,vans,boats, etc,water dispensers, minibar, refrigerators,freezer, ice maker, beers coolers, merchandisers, dehumidifier, refrigerated islands and kitchen freezers.
Q5: How much does a refrigeration part cost?
A5: Factory price for you, not cheapest but the competitive price with good quality.
Q6:What’s voltage CHINAMFG compressor available?
Q6:We have 220-240v and 110-120v for 50hz-60hz in AC compressor. And we have 12/24v/48v in DC Compressors. Depend on customer requirements.
Q7:What certifications do CHINAMFG have?
A7:We have UL, CCC, CE, CB, ETL, TUV, RoHS certifications in compressor.
Q8:What’s our CHINAMFG competitive advantages?
A8:a)More compressor model—–We have DC compressor, AC compressor and frequency conversion series compressor.
b)Lower noisy about compressor
c)Stable quality—–Coming from good material and technology.
d)Good service —–Satisfaction service before and after sale.
| Kundendienst: | Technical Support |
|---|---|
| Garantie: | 1 Year |
| Lubrication Style: | Lubricated |
| Proben: |
US$ 34/Piece
1 Stück (Mindestbestellmenge) | Muster bestellen |
|---|
| Anpassung: |
Verfügbar
|
|
|---|
.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}
| Versandkosten:
Geschätzte Frachtkosten pro Einheit. |
about shipping cost and estimated delivery time. |
|---|
| Payment Method: |
|
|---|---|
|
Initial Payment Full Payment |
| Currency: | US$ |
|---|
| Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
|---|
.webp)
What is the role of air compressors in power generation?
Air compressors play a significant role in power generation, supporting various operations and equipment within the industry. Here are some key roles of air compressors in power generation:
1. Combustion Air Supply:
Air compressors are used to supply compressed air for the combustion process in power generation. In fossil fuel power plants, such as coal-fired or natural gas power plants, compressed air is required to deliver a steady flow of air to the burners. The compressed air helps in the efficient combustion of fuel, enhancing the overall performance and energy output of the power plant.
2. Instrumentation and Control:
Air compressors are utilized for instrumentation and control systems in power generation facilities. Compressed air is used to operate pneumatic control valves, actuators, and other pneumatic devices that regulate the flow of steam, water, and gases within the power plant. The reliable and precise control provided by compressed air ensures efficient and safe operation of various processes and equipment.
3. Cooling and Ventilation:
In power generation, air compressors are involved in cooling and ventilation applications. Compressed air is used to drive air-operated cooling fans and blowers, providing adequate airflow for cooling critical components such as generators, transformers, and power electronics. The compressed air also assists in maintaining proper ventilation in control rooms, substations, and other enclosed spaces, helping to dissipate heat and ensure a comfortable working environment.
4. Cleaning and Maintenance:
Air compressors are employed for cleaning and maintenance tasks in power generation facilities. Compressed air is utilized to blow away dust, dirt, and debris from equipment, machinery, and electrical panels. It helps in maintaining the cleanliness and optimal performance of various components, reducing the risk of equipment failure and improving overall reliability.
5. Pneumatic Tools and Equipment:
In power generation plants, air compressors provide the necessary compressed air for operating pneumatic tools and equipment. These tools include impact wrenches, pneumatic drills, grinders, and sandblasting equipment, which are utilized for installation, maintenance, and repair tasks. The high-pressure air generated by compressors enables efficient and reliable operation of these tools, enhancing productivity and reducing manual effort.
6. Nitrogen Generation:
Sometimes, air compressors are used in power generation for nitrogen generation. Compressed air is passed through a nitrogen generator system, which separates nitrogen from other components of air, producing a high-purity nitrogen gas stream. Nitrogen is commonly used in power plant applications, such as purging systems, blanketing in transformers, and generator cooling, due to its inert properties and low moisture content.
7. Start-up and Emergency Systems:
Air compressors are an integral part of start-up and emergency systems in power generation. Compressed air is utilized to power pneumatic starters for gas turbines, providing the initial rotation needed to start the turbine. In emergency situations, compressed air is also used to actuate emergency shutdown valves, safety systems, and fire suppression equipment, ensuring the safe operation and protection of the power plant.
Overall, air compressors contribute to the efficient and reliable operation of power generation facilities, supporting combustion processes, control systems, cooling, cleaning, and various other applications critical to the power generation industry.
.webp)
Wie hoch ist die Energieeffizienz moderner Luftkompressoren?
Die Energieeffizienz moderner Luftkompressoren hat sich dank technologischer und konstruktiver Fortschritte deutlich verbessert. Im Folgenden finden Sie einen detaillierten Überblick über die Energieeffizienzmerkmale und -faktoren, die zur Effizienz moderner Luftkompressoren beitragen:
Technologie für drehzahlvariable Antriebe (VSD):
Viele moderne Luftkompressoren nutzen die Drehzahlregelung (auch Frequenzumrichter genannt). Diese Technologie ermöglicht es dem Kompressormotor, seine Drehzahl an den Druckluftbedarf anzupassen. Durch die Anpassung der Motordrehzahl an den benötigten Luftstrom vermeiden Drehzahlregler-Kompressoren übermäßigen Energieverbrauch in Zeiten geringen Bedarfs und erzielen so im Vergleich zu Kompressoren mit fester Drehzahl erhebliche Energieeinsparungen.
Reduzierung von Luftleckagen:
Luftverluste sind ein häufiges Problem in Druckluftsystemen und können zu erheblichen Energieverschwendungen führen. Moderne Kompressoren verfügen daher oft über verbesserte Dichtungen und fortschrittliche Steuerungssysteme, um Luftverluste zu minimieren. Durch die Reduzierung von Luftverlusten kann der Kompressor den optimalen Druck effizienter aufrechterhalten, was zu Energieeinsparungen führt.
Effizientes Motordesign:
Der Motor eines Luftkompressors spielt eine entscheidende Rolle für dessen Energieeffizienz. Moderne Kompressoren sind mit hocheffizienten Elektromotoren ausgestattet, die die geltenden Energieeffizienzstandards erfüllen oder übertreffen. Diese Motoren sind so konstruiert, dass sie Energieverluste minimieren und effizienter arbeiten, wodurch der Gesamtstromverbrauch sinkt.
Optimierte Steuerungssysteme:
Moderne Luftkompressoren sind mit fortschrittlichen Steuerungssystemen ausgestattet, die ihre Leistung und ihren Energieverbrauch optimieren. Diese Systeme überwachen verschiedene Parameter wie Luftdruck, Temperatur und Luftstrom und passen den Kompressorbetrieb entsprechend an. Durch die präzise Steuerung der Kompressorleistung zur Anpassung an den Bedarf gewährleisten diese Systeme einen effizienten und energiesparenden Betrieb.
Luftspeicherung und -verteilung:
Effiziente Druckluftspeicher- und -verteilungssysteme sind unerlässlich, um Energieverluste in Druckluftsystemen zu minimieren. Moderne Kompressoren verfügen häufig über ausreichend dimensionierte und isolierte Druckluftspeicher sowie durchdachte Rohrleitungssysteme, die Druckverluste reduzieren und die Wärmeübertragung minimieren. Diese Maßnahmen tragen zu einer gleichmäßigen und effizienten Druckluftversorgung im gesamten System bei und reduzieren so Energieverschwendung.
Energiemanagement und -überwachung:
Moderne Luftkompressoren verfügen teilweise über Energiemanagement- und Überwachungssysteme, die Echtzeitdaten zu Energieverbrauch und Leistung liefern. Mithilfe dieser Systeme können Bediener Energieineffizienzen erkennen, die Kompressoreinstellungen optimieren und energiesparende Maßnahmen umsetzen.
Es ist wichtig zu beachten, dass die Energieeffizienz eines Luftkompressors von Faktoren wie dem jeweiligen Modell, der Größe und dem Anwendungsbereich abhängt. Hersteller geben häufig Energieeffizienzwerte oder -spezifikationen für ihre Kompressoren an, die beim Vergleich verschiedener Modelle und der Auswahl des effizientesten Modells für eine bestimmte Anwendung hilfreich sein können.
Moderne Luftkompressoren verfügen über diverse energiesparende Technologien und Konstruktionsmerkmale, die ihre Effizienz steigern. Die Investition in einen energieeffizienten Luftkompressor senkt nicht nur die Betriebskosten, sondern trägt auch zu mehr Nachhaltigkeit bei, indem der Energieverbrauch minimiert und die CO₂-Emissionen reduziert werden.
.webp)
Wie wird der Luftdruck in Luftkompressoren gemessen?
Der Luftdruck in Luftkompressoren wird üblicherweise in einer der beiden gängigen Einheiten gemessen: Pfund pro Quadratzoll (PSI) oder Bar. Hier eine kurze Erklärung, wie der Luftdruck in Luftkompressoren gemessen wird:
1. Pfund pro Quadratzoll (PSI): PSI ist die gebräuchlichste Einheit zur Druckmessung bei Luftkompressoren, insbesondere in Nordamerika. Sie gibt die Kraft an, die von einem Pfund auf eine Fläche von einem Quadratzoll ausgeübt wird. Manometer an Luftkompressoren zeigen den Druck häufig in PSI an, sodass Benutzer den Druck überwachen und entsprechend anpassen können.
2. Bar: Bar ist eine weitere, in Luftkompressoren gebräuchliche Druckeinheit, insbesondere in Europa und vielen anderen Teilen der Welt. Es handelt sich um eine metrische Druckeinheit, die 100.000 Pascal (Pa) entspricht. Luftkompressoren können Manometer besitzen, die Messwerte in Bar anzeigen und somit eine alternative Messmöglichkeit für Anwender in diesen Regionen bieten.
Zur Messung des Luftdrucks in einem Kompressor wird üblicherweise ein Manometer am Kompressorausgang oder am Druckluftbehälter installiert. Das Manometer misst die Kraft der Druckluft und zeigt den Messwert in der angegebenen Einheit, z. B. PSI oder bar, an.
Es ist wichtig zu beachten, dass der auf dem Manometer angezeigte Luftdruck den Druck an einem bestimmten Punkt im Druckluftsystem darstellt, typischerweise am Auslass oder am Druckluftbehälter. Der tatsächliche Druck am Einsatzort kann aufgrund von Faktoren wie Druckabfall in den Druckluftleitungen oder durch Verschraubungen und Werkzeuge verursachten Einschränkungen abweichen.
Bei der Verwendung eines Kompressors ist es unerlässlich, den Druck auf den für die jeweilige Anwendung erforderlichen Wert einzustellen. Verschiedene Werkzeuge und Geräte haben unterschiedliche Druckanforderungen, und ein Überschreiten des empfohlenen Drucks kann zu Schäden oder unsicherem Betrieb führen. Die meisten Kompressoren ermöglichen es dem Benutzer, den Ausgangsdruck mithilfe eines Druckreglers oder eines ähnlichen Steuerungsmechanismus anzupassen.
Die regelmäßige Überwachung des Luftdrucks in einem Luftkompressor ist entscheidend für optimale Leistung, Effizienz und sicheren Betrieb. Durch das Verständnis der Maßeinheiten und den sachgemäßen Einsatz von Manometern können Anwender die gewünschten Luftdruckwerte in ihren Kompressorsystemen aufrechterhalten.


editor by CX 2023-10-16