Descrição do produto
Descrição do produto
M/HBP R134A (110V-120V~60HZ/220V-240V~50HZ) Refrigeration Compressors Special for Home Dehumidifiers
Adopting high-quality components, SIXIHU (WEST LAKE) DIS. refrigeration compressors are always environmental friendly, high efficient, and widely praised by customers in the refrigeration industry due to its low noise, high performance, and long service life.
Features:
1. Low Noise:
– There are 2 welding methods for the compressor casing: flange butt welding or insert welding. The thickness, shape, and internal cavity size of the shell have a significant impact on noise.
– There are 2 fixing methods for the movement: suspension spring type and seat spring type, with the seat spring compressor having less noise and vibration.
2. High Performance:
– Equipped with professional valve components. The valve group is the heart of the compressor and plays a significant role in the performance of the compressor.
3. Long Service Life:
– The crankshaft and connecting rod have good performance and are resistant to friction.
4. High Efficiency & Eco-friendly:
– As the power in a hermetic compressor, an electric motor converts electrical energy into mechanical energy, driving the piston to compress refrigerant vapor, enabling the refrigerant to circulate in the refrigeration system and achieve the purpose of refrigeration
Product Parameters
Compressor Technical Data: M/HBP R134A 110V-120V~60HZ/220V-240V~50HZ
| Serial | Modelo | HP | V/Hz | Displacement (cm3) | Cooling Capacity ASHRAE | Motor type | Starting Device | Starting capacitor (uF) | Running capacitor (uF) | Cooling | Certificate | |||||||||||||||
| -15ºC(5F) | -10ºC(10F) | -5ºC(23F) | 0ºC(32F) | Test Conditions: 7.2ºC(45F) | 10ºC(50F) | |||||||||||||||||||||
| W | Btu/h | W | Btu/h | W | Btu/h | W | Btu/h | Capacity (W) | Capacity (Btu/h) | lnput Power(W) | Current (A) | COP (W/W) | EER (Btu/Wh) | W | Btu/h | |||||||||||
| L | GQR30TC | 1/10 | 220-240V/50-60Hz | 3.0 | 97 | 331 | 125 | 427 | 145 | 495 | 185 | 631 | 245 | 836 | 129 | 0.9 | 1.9 | 6.48 | 275 | 938 | RSIR | PTC/Heavy Hammer PTC/Current Starting Relay | / | / | F | CCC |
| GQR35TC | 1/9 | 3.5 | 135 | 461 | 175 | 597 | 195 | 665 | 265 | 904 | 385 | 1314 | 185 | 1.1 | 2.1 | 7.17 | 420 | 1433 | RSIR | / | / | F | CCC | |||
| GQR45TC | 1/6 | 4.5 | 176 | 601 | 230 | 785 | 280 | 955 | 350 | 1194 | 450 | 1535 | 204 | 1.2 | 2.2 | 7.51 | 485 | 1655 | RSIR | / | / | F | CCC | |||
| ML | GQR55TC | 1/6+ | 5.5 | 245 | 836 | 310 | 1058 | 390 | 1331 | 525 | 1791 | 575 | 1962 | 273 | 1.5 | 2.1 | 7.19 | 615 | 2098 | RSIR | / | / | F | CCC | ||
| GQR60TC | 1/4 | 6.5 | 335 | 1143 | 435 | 1484 | 545 | 1860 | 665 | 2269 | 705 | 2405 | 306 | 1.9 | 2.3 | 7.86 | 745 | 2542 | RSIR | / | / | F | CCC | |||
| GQR70TC | 1/4 | 7.0 | 370 | 1262 | 480 | 1638 | 595 | 2030 | 720 | 2457 | 765 | 2610 | 364 | 2.1 | 2.1 | 7.17 | 805 | 2747 | RSIR | / | / | F | CCC | |||
| MQ | GQR80TC | 1/4+ | 8.0 | 420 | 1433 | 550 | 1877 | 680 | 2320 | 810 | 2764 | 855 | 2917 | 388 | 2.2 | 2.2 | 7.52 | 895 | 3054 | CSIR | Heavy Hammer Current Starting Relay | 80 | / | F | CCC | |
| GQR90TC | 1/3- | 9.0 | 474 | 1617 | 621 | 2119 | 768 | 2620 | 910 | 3105 | 955 | 3258 | 434 | 2.3 | 2.2 | 7.51 | 995 | 3395 | CSIR | 80 | / | F | CCC | |||
| GQR11TC | 3/8 | 11.0 | 536 | 1829 | 702 | 2395 | 868 | 2962 | 1034 | 3528 | 1079 | 3682 | 469 | 2.9 | 2.3 | 7.85 | 1119 | 3818 | CSIR | 80 | / | F | CCC | |||
| MD | GQR12TC | 3/8+ | 12.0 | 606 | 2068 | 793 | 2706 | 981 | 3347 | 1168 | 3985 | 1208 | 4122 | 549 | 3.4 | 2.2 | 7.51 | 1248 | 4258 | CSIR | 80 | / | F | CCC | ||
| GQR14TC | 1/2 | 14.0 | 685 | 2337 | 896 | 3057 | 1108 | 3780 | 1320 | 4504 | 1365 | 4657 | 593 | 3.6 | 2.3 | 7.85 | 1305 | 4453 | CSIR | 80 | / | F | CCC | |||
| GQR16TC | 1/2+ | 16.0 | 754 | 2573 | 1012 | 3453 | 1252 | 4272 | 1492 | 5091 | 1535 | 5237 | 667 | 4.0 | 2.3 | 7.85 | 1575 | 5374 | CSIR | 80 | / | F | CCC | |||
| Serial | Modelo | HP | V/Hz | Displacement (cm3) | Cooling Capacity ASHRAE | Motor type | Starting Device | Starting capacitor (uF) | Running capacitor (uF) | Cooling | Certificate | |||||||||||||||
| -15ºC(5F) | -10ºC(10F) | -5ºC(23F) | 0ºC(32F) | Test Conditions: 7.2ºC(45F) | 10ºC(50F) | |||||||||||||||||||||
| W | Btu/h | W | Btu/h | W | Btu/h | W | Btu/h | Capacity (W) | Capacity (Btu/h) | lnput Power(W) | Current (A) | COP (W/W) | EER (Btu/Wh) | W | Btu/h | |||||||||||
| L | GQR30TCD | 1/10 | 110-120V/60Hz | 3.0 | 118 | 403 | 150 | 512 | 174 | 594 | 225 | 768 | 295 | 1007 | 134 | 1.8 | 2.2 | 7.51 | 340 | 1160 | RSIR | PTC/Heavy Hammer PTC/Current Starting Relay | / | / | F | CCC |
| GQR35TCD | 1/9 | 3.5 | 162 | 553 | 210 | 717 | 234 | 798 | 320 | 1092 | 465 | 1587 | 211 | 2.0 | 2.2 | 7.52 | 504 | 1720 | RSIR | / | / | F | CCC | |||
| ML | GQR45TCD | 1/6 | 4.5 | 210 | 717 | 275 | 938 | 340 | 1160 | 420 | 1433 | 540 | 1842 | 245 | 2.1 | 2.2 | 7.52 | 580 | 1979 | RSIR | / | / | F | CCC | ||
| GQR55TCD | 1/6+ | 5.5 | 310 | 1058 | 390 | 1331 | 480 | 1638 | 610 | 2081 | 665 | 2269 | 316 | 2.9 | 2.1 | 7.18 | 720 | 2457 | RSIR | / | / | F | CCC | |||
| GQR60TCD | 1/4 | 6.5 | 378 | 1290 | 510 | 1740 | 650 | 2218 | 731 | 2494 | 786 | 2682 | 341 | 3.5 | 2.3 | 7.86 | 841 | 2869 | RSIR | / | / | F | CCC | |||
| GQR70TCD | 1/4 | 7.0 | 430 | 1467 | 545 | 1860 | 750 | 2559 | 806 | 2750 | 862 | 2941 | 410 | 3.8 | 2.1 | 7.17 | 917 | 3129 | RSIR | / | / | F | CCC | |||
| MQ | GQR80TCD | 1/4+ | 8.0 | 470 | 1604 | 625 | 2133 | 820 | 2798 | 907 | 3095 | 964 | 3289 | 438 | 4.2 | 2.2 | 7.51 | 1019 | 3477 | CSIR | Heavy Hammer Current Starting Relay | 93-169 | / | F | CCC | |
| GQR90TCD | 1/3- | 9.1 | 530 | 1808 | 695 | 2371 | 890 | 3037 | 1019 | 3477 | 1074 | 3664 | 488 | 3.8 | 2.2 | 7.51 | 1129 | 3852 | CSIR | 93-169 | / | F | CCC | |||
| GQR11TCD | 3/8 | 11.0 | 600 | 2047 | 772 | 2634 | 954 | 3255 | 1100 | 3753 | 1155 | 3941 | 502 | 5.2 | 2.3 | 7.85 | 1210 | 4129 | CSIR | 93-169 | / | F | CCC | |||
| MD | GQR12TCD | 3/8+ | 12.8 | 678 | 2313 | 872 | 2975 | 1034 | 3528 | 1270 | 4333 | 1325 | 4521 | 602 | 5.5 | 2.2 | 7.51 | 1380 | 4709 | CSIR | 93-169 | / | F | CCC | ||
| GQR14TCD | 1/2 | 14.2 | 758 | 2586 | 985 | 3361 | 1218 | 4156 | 1402 | 4784 | 1457 | 4971 | 633 | 5.8 | 2.3 | 7.85 | 1512 | 5159 | CSIR | 93-169 | / | F | CCC | |||
| GQR16TCD | 1/2+ | 15.3 | 829 | 2829 | 1113 | 3798 | 1375 | 4692 | 1641 | 5599 | 1696 | 5787 | 737 | 6.0 | 2.3 | 7.85 | 1751 | 5974 | CSIR | 93-169 | / | F | CCC | |||
→ More Compressor Please Click to Contact Us!
Company Profile
Certificações
With abundant technique force,we have our own researching, developing, manufacturing, inspecting and testingcenters, and imported the international advanced high-tech equipments. Our company has passed the ISO9001,ISO14001,OHS18001 international management system certificates. The products have got UL,ETL,CE,CB,and CCC certificates. Our products are not only selling strongly in more than 30 provincesand municipality,but also largely exporting to Europe,America,Australia,Middle East, Africa and South Asia. We have won an excellent reputation from the customers and friends by our product quality, price versus performance ratio and service.
Perguntas frequentes
Q1: Are you a manufacturer or trader?
A1: ZHangZhoug Maidi Refrigeration Technology Co., Ltd. is a Hi-tech enterprise. We own the standard plant and office building which covering 21, 000 square meters. With abundant technique force, we have our own researching, developing, manufacturing, inspecting and testing centers, and imported the international advanced equipments.
Q2: How to match sikelan compressor to refrigeration?
A2: We have a professional team of engineers who provide technical support and online guidance on product installation and replacement.
Q3: How do you ensure quality?
A3: We have a dedicated product research and testing center with authoritative quality management system certification: ISO9001/ISO14001/OHS18001.
Q4:What’s CHINAMFG compressor usage scenario?
Q4:Our product could use in mobile applications e.g. cooling boxes,vans,boats, etc,water dispensers, minibar, refrigerators,freezer, ice maker, beers coolers, merchandisers, dehumidifier, refrigerated islands and kitchen freezers.
Q5: How much does a refrigeration part cost?
A5: Factory price for you, not cheapest but the competitive price with good quality.
Q6:What’s voltage CHINAMFG compressor available?
Q6:We have 220-240v and 110-120v for 50hz-60hz in AC compressor. And we have 12/24v/48v in DC Compressors. Depend on customer requirements.
Q7:What certifications do CHINAMFG have?
A7:We have UL, CCC, CE, CB, ETL, TUV, RoHS certifications in compressor.
Q8:What’s our CHINAMFG competitive advantages?
A8:a)More compressor model—–We have DC compressor, AC compressor and frequency conversion series compressor.
b)Lower noisy about compressor
c)Stable quality—–Coming from good material and technology.
d)Good service —–Satisfaction service before and after sale.
| Serviço pós-venda: | Technical Support |
|---|---|
| Garantia: | 1 Year |
| Lubrication Style: | Lubricated |
| Exemplos: |
US$ 34/Piece
1 unidade (pedido mínimo) | Solicitar amostra |
|---|
| Personalização: |
Disponível
|
|
|---|
.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}
| Custo do frete:
Frete estimado por unidade. |
about shipping cost and estimated delivery time. |
|---|
| Payment Method: |
|
|---|---|
|
Initial Payment Full Payment |
| Currency: | US$ |
|---|
| Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
|---|
.webp)
What is the role of air compressors in power generation?
Air compressors play a significant role in power generation, supporting various operations and equipment within the industry. Here are some key roles of air compressors in power generation:
1. Combustion Air Supply:
Air compressors are used to supply compressed air for the combustion process in power generation. In fossil fuel power plants, such as coal-fired or natural gas power plants, compressed air is required to deliver a steady flow of air to the burners. The compressed air helps in the efficient combustion of fuel, enhancing the overall performance and energy output of the power plant.
2. Instrumentation and Control:
Air compressors are utilized for instrumentation and control systems in power generation facilities. Compressed air is used to operate pneumatic control valves, actuators, and other pneumatic devices that regulate the flow of steam, water, and gases within the power plant. The reliable and precise control provided by compressed air ensures efficient and safe operation of various processes and equipment.
3. Cooling and Ventilation:
In power generation, air compressors are involved in cooling and ventilation applications. Compressed air is used to drive air-operated cooling fans and blowers, providing adequate airflow for cooling critical components such as generators, transformers, and power electronics. The compressed air also assists in maintaining proper ventilation in control rooms, substations, and other enclosed spaces, helping to dissipate heat and ensure a comfortable working environment.
4. Cleaning and Maintenance:
Air compressors are employed for cleaning and maintenance tasks in power generation facilities. Compressed air is utilized to blow away dust, dirt, and debris from equipment, machinery, and electrical panels. It helps in maintaining the cleanliness and optimal performance of various components, reducing the risk of equipment failure and improving overall reliability.
5. Pneumatic Tools and Equipment:
In power generation plants, air compressors provide the necessary compressed air for operating pneumatic tools and equipment. These tools include impact wrenches, pneumatic drills, grinders, and sandblasting equipment, which are utilized for installation, maintenance, and repair tasks. The high-pressure air generated by compressors enables efficient and reliable operation of these tools, enhancing productivity and reducing manual effort.
6. Nitrogen Generation:
Sometimes, air compressors are used in power generation for nitrogen generation. Compressed air is passed through a nitrogen generator system, which separates nitrogen from other components of air, producing a high-purity nitrogen gas stream. Nitrogen is commonly used in power plant applications, such as purging systems, blanketing in transformers, and generator cooling, due to its inert properties and low moisture content.
7. Start-up and Emergency Systems:
Air compressors are an integral part of start-up and emergency systems in power generation. Compressed air is utilized to power pneumatic starters for gas turbines, providing the initial rotation needed to start the turbine. In emergency situations, compressed air is also used to actuate emergency shutdown valves, safety systems, and fire suppression equipment, ensuring the safe operation and protection of the power plant.
Overall, air compressors contribute to the efficient and reliable operation of power generation facilities, supporting combustion processes, control systems, cooling, cleaning, and various other applications critical to the power generation industry.
.webp)
Qual é a eficiência energética dos compressores de ar modernos?
A eficiência energética dos compressores de ar modernos melhorou significativamente devido aos avanços na tecnologia e no design. Aqui está uma análise detalhada dos recursos e fatores que contribuem para a eficiência energética dos compressores de ar modernos:
Tecnologia de acionamento de velocidade variável (VSD):
Muitos compressores de ar modernos utilizam a tecnologia de acionamento de velocidade variável (VSD), também conhecida como acionamento de frequência variável (VFD). Essa tecnologia permite que o motor do compressor ajuste sua velocidade de acordo com a demanda de ar comprimido. Ao adequar a velocidade do motor à vazão de ar necessária, os compressores VSD podem evitar o consumo excessivo de energia durante períodos de baixa demanda, resultando em economia de energia significativa em comparação com compressores de velocidade fixa.
Redução de vazamentos de ar:
Vazamentos de ar são um problema comum em sistemas de ar comprimido e podem levar a um desperdício considerável de energia. Os compressores de ar modernos geralmente apresentam vedação aprimorada e sistemas de controle avançados para minimizar vazamentos de ar. Ao reduzir os vazamentos, o compressor consegue manter os níveis de pressão ideais com mais eficiência, resultando em economia de energia.
Design eficiente do motor:
O motor de um compressor de ar desempenha um papel crucial na sua eficiência energética. Os compressores modernos incorporam motores elétricos de alta eficiência que atendem ou superam os padrões de eficiência energética estabelecidos. Esses motores são projetados para minimizar as perdas de energia e operar com maior eficiência, reduzindo o consumo geral de energia.
Sistemas de controle otimizados:
Sistemas de controle avançados são integrados aos compressores de ar modernos para otimizar seu desempenho e consumo de energia. Esses sistemas monitoram diversos parâmetros, como pressão, temperatura e vazão do ar, e ajustam a operação do compressor de acordo. Ao controlar com precisão a potência de saída do compressor para atender à demanda, esses sistemas garantem uma operação eficiente e com economia de energia.
Armazenamento e distribuição de ar:
Sistemas eficientes de armazenamento e distribuição de ar são essenciais para minimizar as perdas de energia em sistemas de ar comprimido. Os compressores de ar modernos geralmente incluem tanques de armazenamento de ar dimensionados e isolados adequadamente, além de sistemas de tubulação bem projetados que reduzem as quedas de pressão e minimizam a transferência de calor. Essas medidas ajudam a manter um fornecimento consistente e eficiente de ar comprimido em todo o sistema, reduzindo o desperdício de energia.
Gestão e Monitoramento de Energia:
Alguns compressores de ar modernos possuem sistemas de gerenciamento e monitoramento de energia que fornecem dados em tempo real sobre o consumo de energia e o desempenho. Esses sistemas permitem que os operadores identifiquem ineficiências energéticas, otimizem as configurações do compressor e implementem práticas de economia de energia.
É importante observar que a eficiência energética de um compressor de ar também depende de fatores como o modelo específico, o tamanho e a aplicação. Os fabricantes geralmente fornecem classificações ou especificações de eficiência energética para seus compressores, o que pode ajudar na comparação de diferentes modelos e na seleção da opção mais eficiente para uma determinada aplicação.
De modo geral, os compressores de ar modernos incorporam diversas tecnologias e elementos de design que economizam energia para aumentar sua eficiência. Investir em um compressor de ar com alta eficiência energética não só reduz os custos operacionais, como também contribui para a sustentabilidade, minimizando o consumo de energia e reduzindo as emissões de carbono.
.webp)
Como a pressão do ar é medida em compressores de ar?
A pressão do ar em compressores é normalmente medida usando uma das duas unidades comuns: libras por polegada quadrada (PSI) ou bar. Aqui está uma breve explicação de como a pressão do ar é medida em compressores:
1. Libras por polegada quadrada (PSI): PSI é a unidade de medida de pressão mais utilizada em compressores de ar, especialmente na América do Norte. Representa a força exercida por uma libra de força sobre uma área de uma polegada quadrada. Os manômetros de compressores de ar geralmente exibem leituras de pressão em PSI, permitindo que os usuários monitorem e ajustem a pressão conforme necessário.
2. Bar: O bar é outra unidade de pressão comumente usada em compressores de ar, principalmente na Europa e em muitas outras partes do mundo. É uma unidade métrica de pressão equivalente a 100.000 pascais (Pa). Os compressores de ar podem ter manômetros que exibem leituras em bar, oferecendo uma opção de medição alternativa para usuários nessas regiões.
Para medir a pressão do ar em um compressor de ar, um manômetro é normalmente instalado na saída do compressor ou no reservatório. O manômetro é projetado para medir a força exercida pelo ar comprimido e exibir a leitura na unidade especificada, como PSI ou bar.
É importante observar que a pressão de ar indicada no manômetro representa a pressão em um ponto específico do sistema do compressor de ar, normalmente na saída ou no reservatório. A pressão real no ponto de uso pode variar devido a fatores como queda de pressão nas linhas de ar ou restrições causadas por conexões e ferramentas.
Ao usar um compressor de ar, é essencial ajustar a pressão para o nível apropriado para a aplicação específica. Diferentes ferramentas e equipamentos têm diferentes requisitos de pressão, e exceder a pressão recomendada pode causar danos ou operação insegura. A maioria dos compressores de ar permite que os usuários ajustem a pressão de saída usando um regulador de pressão ou mecanismo de controle similar.
O monitoramento regular da pressão do ar em um compressor de ar é crucial para garantir desempenho ideal, eficiência e operação segura. Ao compreender as unidades de medida e usar manômetros adequadamente, os usuários podem manter os níveis de pressão de ar desejados em seus sistemas de compressores de ar.


editor by CX 2023-10-16